IM Series Flow Switch

Features
• No Moving Parts
• 316L Stainless Steel
• Temperatures to +250F
• Pressures to 2000 PSIG
• Low Flow Rate Detection
• ¼” Tubing Connection
• Reliable and Cost Effective
• Simple Easy Field Calibration

Applications

• Pump Protection: Automatic shut down on low or no flow
• Bearing Lubrication: Detects loss of lubricant flow
• Seal Leakage: Verifies positive seal flow or detects excessive leakage indicating maintenance requirement
• Chemical Feed and Metering Pumps: Indicates low or no flow of chemical additives to process
• Spray Nozzles: Detects nozzle blockage in coating applications
• Relief Valve/Rupture Disks: Alarms on flow or leakage of safety relief valves or rupture disks
• Chiller Lines: Automatic shut down of chillers on low or no flow
• Analyzer/ Gas Chromatographs: Confirms continuous sample flow to instruments

Operation
The IM series in-line flow switch is designed to easily adapt to ¼” tubing. Please refer to the IX or FX series for larger line sizes. These switches offer an extremely reliable and repeatable instrument for industrial process control and feature no moving parts exposed to the product being monitored. The device operates by measuring a temperature differential between a heated and a reference temperature sensor. Within the body of the sensor head are the four tubes as shown in figure 1. The temperature differential is greatest at no flow and changes as flow is achieved across the sensor. This allows use in applications requiring a simple flow/no flow detection and for set-points at a predetermined flow rate. Many different flow ranges are shown in the set-point range section. A conversion table is also provided to convert different engineering units.
Extremely low flow rates can be detected with a typical turn down ratio of 300:1. The principle of operation allows this flow switch to be used in practically all liquids, gases and slurries.

The electronics are available with single or dual switch points. The instrument can be easily field programmed to detect an increase or decrease of flow. Relay outputs are standard and are offered with several different configurations and contact ratings.